Respiratory motion compensation for simultaneous PET/MR based on highly undersampled MR data.

Thumbnail
Date
2016-12
ICR Author
Wetscherek, Andreas
Author
Rank, CM
Heußer, T
Wetscherek, A
Freitag, MT
Sedlaczek, O
Schlemmer, H-P
Kachelrieß, M
Show allShow less
Type
Journal Article
Metadata
Show full item record
Abstract
Purpose Positron emission tomography (PET) of the thorax region is impaired by respiratory patient motion. To account for motion, the authors propose a new method for PET/magnetic resonance (MR) respiratory motion compensation (MoCo), which uses highly undersampled MR data with acquisition times as short as 1 min/bed.Methods The proposed PET/MR MoCo method (4D jMoCo PET) uses radial MR data to estimate the respiratory patient motion employing MR joint motion estimation and image reconstruction with temporal median filtering. Resulting motion vector fields are incorporated into the system matrix of the PET reconstruction. The proposed approach is evaluated for the thorax region utilizing a PET/MR simulation with 1 min MR acquisition time and simultaneous PET/MR measurements of six patients with MR acquisition times of 1 and 5 min and radial undersampling factors of 11.2 and 2.2, respectively. Reconstruction results are compared to 3D PET, 4D gated PET and a standard MoCo method (4D sMoCo PET), which performs iterative image reconstruction and motion estimation sequentially. Quantitative analysis comprises the parameters SUV mean , SUV max , full width at half-maximum/lesion volume, contrast and signal-to-noise ratio.Results For simulated PET data, our quantitative analysis shows that the proposed 4D jMoCo PET approach with temporal filtering achieves the best quantification accuracy of all tested reconstruction methods with a mean absolute deviation of 2.3% when compared to the ground truth. For measured PET patient data, the mean absolute deviation of 4D jMoCo PET using a 1 min MR acquisition for motion estimation is 2.1% relative to the 5 min MR acquisition. This demonstrates a robust behavior even in case of strong undersampling at MR acquisition times as short as 1 min. In contrast, 4D sMoCo PET shows considerable reduction of quantification accuracy for the 1 min MR acquisition time. Relative to 3D PET, the proposed 4D jMoCo PET approach with temporal filtering yields an average increase of SUV mean , SUV max , and contrast of 29.9% and 13.8% for simulated and measured PET data, respectively.Conclusions Employing artifact-robust motion estimation enables PET/MR respiratory MoCo with MR acquisition times as short as 1 min/bed improving PET image quality and quantification accuracy.
URI
https://repository.icr.ac.uk/handle/internal/2142
DOI
https://doi.org/10.1118/1.4966128
Collections
  • Radiotherapy and Imaging
Subject
Humans
Positron-Emission Tomography
Magnetic Resonance Imaging
Artifacts
Respiration
Movement
Image Processing, Computer-Assisted
Adult
Aged
Aged, 80 and over
Middle Aged
Female
Male
Signal-To-Noise Ratio
Multimodal Imaging
Research team
Radiotherapy Physics Modelling
Language
eng
License start date
2016-12
Citation
Medical physics, 2016, 43 (12), pp. 6234 - ?