Tracheo-oesophageal fistula: a delayed complication of missed inhaled magnetic toys.

Loading...
Thumbnail Image

Embargo End Date

ICR Authors

Authors

Yang, W
Jones, M
Mallick, S

Document Type

Journal Article

Date

2018-02-01

Date Accepted

2018-01-27

Abstract

Delayed diagnosis of tracheobronchial foreign body (FB) aspiration is not uncommon in children. It occurs when symptoms are underappreciated and/or radiological findings are overlooked. In such cases serious complications can arise, which make the diagnosis and removal of the FB much more difficult. Here, we present a case where FB aspiration was misdiagnosed as asthma after a radio-opaque FB on the chest radiograph was missed, leading to formation of a tracheo-oesophageal fistula as a rare delayed complication.

Citation

Journal of Surgical Case Reports, 2018, 2018 (2),