Quantitative Real-Time MRI for the Assessment of Gastric Motility
Loading...
Embargo End Date
ICR Authors
Authors
Neubauer, L
Forstreuter, L
Winter, F
Mankertz, F
Wielputz, MO
Grajecki, DS
Steveling, A
Aghdassi, AA
Zeissig, S
Blackledge, MD
Voit, D
Frahm, J
Schnell, S
Weitschies, W
Grossmann, L
Forstreuter, L
Winter, F
Mankertz, F
Wielputz, MO
Grajecki, DS
Steveling, A
Aghdassi, AA
Zeissig, S
Blackledge, MD
Voit, D
Frahm, J
Schnell, S
Weitschies, W
Grossmann, L
Document Type
Journal Article
Date
2026-05-01
Date Accepted
Abstract
<jats:title>ABSTRACT</jats:title>
<jats:sec>
<jats:title>Background</jats:title>
<jats:p>Current reference standards for measuring gastric emptying and motility are not considered optimal due to the time required, ionizing radiation, invasiveness, and spatial resolution.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Purpose</jats:title>
<jats:p>To assess gastric motility using novel real‐time dynamic magnetic resonance imaging in combination with static measurements for gastric emptying and training of an automated deep‐learning‐based segmentation pipeline.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Study Type</jats:title>
<jats:p>Prospective.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Participants</jats:title>
<jats:p>The study included 36 healthy volunteers (20 female, mean 24 ± 3 years) and three patients with diagnosed Crohn's disease.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Field Strength/Sequences</jats:title>
<jats:p>Participants ingested water to assess fasting motility and pineapple juice for the postprandial state. 3 T, 3D spoiled gradient echo (GRE) sequence and real‐time spoiled GRE.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Assessment</jats:title>
<jats:p>Gastric emptying was measured by using the gastric volume, while motility was analyzed by tracking changes in the antrum's cross‐sectional area and applying Fast Fourier Transformation. Segmentations were performed using a trained semantic segmentation model.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Statistical Tests</jats:title>
<jats:p>
Linear Mixed Model with continuous dependent variables and fixed effects. Models included a random intercept for participants. Statistical significance was defined as
<jats:italic>p</jats:italic>
= 0.05.
</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Results</jats:title>
<jats:p>
The method enabled volumetric analysis of gastric content from 3D breath‐hold static acquisition and time‐resolved quantification of peristaltic parameters from real‐time FLASH2 imaging at high temporal resolution (here 6.24 fps). Water emptied rapidly and exponentially (
<jats:italic>t</jats:italic>
<jats:sub>1/2</jats:sub>
= 14.77 ± 10.55 min), while juice showed slower emptying (
<jats:italic>t</jats:italic>
<jats:sub>1/2</jats:sub>
= 64.24 ± 11.87 min). Contraction frequencies (fasted: 2.76 ± 0.43 cpm, fed: 2.89 ± 0.43 cpm) and velocities (fasted: 1.67 ± 0.38 mm/s, fed: 1.72 ± 0.37 mm/s) were within physiological ranges, with fasting conditions characterized by stronger occlusion compared to the fed. Measurements taken from three patients proved that the workflow could be used in a clinical context.
</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Data Conclusion</jats:title>
<jats:p>Real‐time MRI with AI‐based analysis enabled quantitative assessment of gastric emptying and motility, revealing physiological peristaltic parameters and state‐dependent differences in occlusion.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Evidence Level</jats:title>
<jats:p>2.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Technical Efficacy</jats:title>
<jats:p>Stage 1.</jats:p>
</jats:sec>
Citation
Journal of Magnetic Resonance Imaging, 2026, 63 (5), pp. 1482 - 1495
Source Title
Journal of Magnetic Resonance Imaging
Publisher
WILEY
ISSN
1053-1807
eISSN
1522-2586
Collections
Research Team
Computational Imaging