Show simple item record

dc.contributor.authorMachiels, M
dc.contributor.authorJin, P
dc.contributor.authorvan Hooft, JE
dc.contributor.authorGurney-Champion, OJ
dc.contributor.authorJelvehgaran, P
dc.contributor.authorGeijsen, ED
dc.contributor.authorJeene, PM
dc.contributor.authorWillemijn Kolff, M
dc.contributor.authorOppedijk, V
dc.contributor.authorRasch, CRN
dc.contributor.authorvan Herk, MB
dc.contributor.authorAlderliesten, T
dc.contributor.authorHulshof, MCCM
dc.date.accessioned2019-05-03T15:33:21Z
dc.date.issued2019-06-03
dc.identifier.citationActa oncologica (Stockholm, Sweden), 2019, 58 (6), pp. 943 - 950
dc.identifier.issn0284-186X
dc.identifier.urihttps://repository.icr.ac.uk/handle/internal/3220
dc.identifier.eissn1651-226X
dc.identifier.doi10.1080/0284186x.2019.1588991
dc.description.abstractObjective: Delineation variation of esophageal tumors remains a large source of geometric uncertainty. In the present study, we investigated the inter- and intra-observer variation in esophageal gross tumor volume (GTV) delineation and the impact of endoscopically implanted fiducial markers on these variations. Material/Methods: Ten esophageal cancer patients with at least two markers endoscopically implanted at the cranial and caudal tumor borders and visible on the planning computed tomography (pCT) were included in this study. Five dedicated gastrointestinal radiation oncologists independently delineated GTVs on the pCT without markers and with markers. The GTV was first delineated on pCTs where markers were digitally removed and next on the original pCT with markers. Both delineation series were executed twice to determine intra-observer variation. For both the inter- and intra-observer analyses, the generalized conformity index (CIgen), and the standard deviation (SD) of the distances between delineated surfaces (i.e., overall, longitudinal, and radial SDs) were calculated. Linear mixed-effect models were used to compare the without and with markers series (α = 0.05). Results: Both the inter- and intra-observer CIgen were significantly larger in the series with markers than in the series without markers (p < .001). For the series without markers vs. with markers, the inter-observer overall SD, longitudinal SD, and radial SD was 0.63 cm vs. 0.22 cm, 1.44 cm vs. 0.42 cm, and 0.26 cm vs. 0.18 cm, respectively (p < .05); moreover, the intra-observer overall SD, longitudinal SD, and radial SD was 0.45 cm vs. 0.26 cm, 1.10 cm vs. 0.41 cm, and 0.22 cm vs. 0.15 cm, respectively (p < .05). Conclusion: The presence of markers at the cranial and caudal tumor borders significantly reduced both inter- and intra-observer GTV delineation variation, especially in the longitudinal direction. Our results endorse the use of markers in GTV delineation for esophageal cancer patients.
dc.formatPrint-Electronic
dc.format.extent943 - 950
dc.languageeng
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS LTD
dc.rights.urihttps://creativecommons.org/licenses/by/4.0
dc.titleReduced inter-observer and intra-observer delineation variation in esophageal cancer radiotherapy by use of fiducial markers.
dc.typeJournal Article
rioxxterms.versionofrecord10.1080/0284186x.2019.1588991
rioxxterms.licenseref.urihttps://creativecommons.org/licenses/by/4.0
rioxxterms.licenseref.startdate2019-06
rioxxterms.typeJournal Article/Review
dc.relation.isPartOfActa oncologica (Stockholm, Sweden)
pubs.issue6
pubs.notesNot known
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/ICR Divisions
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging/Radiotherapy Physics Modelling
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/ICR Divisions
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging/Radiotherapy Physics Modelling
pubs.publication-statusPublished
pubs.volume58
pubs.embargo.termsNot known
icr.researchteamRadiotherapy Physics Modelling
dc.contributor.icrauthorGurney-Champion, Oliver


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record

https://creativecommons.org/licenses/by/4.0
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by/4.0