Show simple item record

dc.contributor.authorShur, J
dc.contributor.authorBlackledge, M
dc.contributor.authorD'Arcy, J
dc.contributor.authorCollins, DJ
dc.contributor.authorBali, M
dc.contributor.authorO'Leach, M
dc.contributor.authorKoh, D-M
dc.date.accessioned2021-04-06T09:40:46Z
dc.date.available2021-04-06T09:40:46Z
dc.date.issued2021-01-19
dc.identifier.citationEuropean radiology experimental, 2021, 5 (1), pp. 2 - ?
dc.identifier.issn2509-9280
dc.identifier.urihttps://repository.icr.ac.uk/handle/internal/4491
dc.identifier.eissn2509-9280
dc.identifier.doi10.1186/s41747-020-00199-6
dc.description.abstractPURPOSE: To evaluate robustness and repeatability of magnetic resonance imaging (MRI) texture features in water and tissue phantom test-retest study. MATERIALS AND METHODS: Separate water and tissue phantoms were imaged twice with the same protocol in a test-retest experiment using a 1.5-T scanner. Protocols were acquired to favour signal-to-noise ratio and resolution. Forty-six features including first order statistics and second-order texture features were extracted, and repeatability was assessed by calculating the concordance correlation coefficient. Separately, base image noise and resolution were manipulated in an in silico experiment, and robustness of features was calculated by assessing percentage coefficient of variation and linear correlation of features with noise and resolution. These simulation data were compared with the acquired data. Features were classified by their degree (high, intermediate, or low) of robustness and repeatability. RESULTS: Eighty percent of the MRI features were repeatable (concordance correlation coefficient > 0.9) in the phantom test-retest experiment. The majority (approximately 90%) demonstrated a strong or intermediate correlation with image acquisition parameter, and 19/46 (41%) and 13/46 (28%) of features were highly robust to noise and resolution, respectively (coefficient of variation < 5%). Agreement between the acquired and simulation data varied, with the range of agreement within feature classes between 11 and 92%. CONCLUSION: Most MRI features were repeatable in a phantom test-retest study. This phantom data may serve as a lower limit of feature MRI repeatability. Robustness of features varies with acquisition parameter, and appropriate features can be selected for clinical validation studies.
dc.formatElectronic
dc.format.extent2 - ?
dc.languageeng
dc.language.isoeng
dc.publisherSPRINGERNATURE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0
dc.titleMRI texture feature repeatability and image acquisition factor robustness, a phantom study and in silico study.
dc.typeJournal Article
dcterms.dateAccepted2020-12-03
rioxxterms.versionVoR
rioxxterms.versionofrecord10.1186/s41747-020-00199-6
rioxxterms.licenseref.urihttps://creativecommons.org/licenses/by/4.0
rioxxterms.licenseref.startdate2021-01-19
rioxxterms.typeJournal Article/Review
dc.relation.isPartOfEuropean radiology experimental
pubs.issue1
pubs.notesNot known
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/ICR Divisions
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging/Computational Imaging
pubs.organisational-group/ICR/Primary Group/Royal Marsden Clinical Units
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/ICR Divisions
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging
pubs.organisational-group/ICR/Primary Group/ICR Divisions/Radiotherapy and Imaging/Computational Imaging
pubs.organisational-group/ICR/Primary Group/Royal Marsden Clinical Units
pubs.publication-statusPublished
pubs.volume5
pubs.embargo.termsNot known
icr.researchteamComputational Imaging
icr.researchteamComputational Imaging
dc.contributor.icrauthorBlackledge, Matthew
dc.contributor.icrauthorCollins, David


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record

https://creativecommons.org/licenses/by/4.0
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by/4.0