Show simple item record

dc.contributor.authorMoghimirad, E
dc.contributor.authorXu, Z
dc.contributor.authorDing, H
dc.contributor.authorBamber, J
dc.contributor.authorHarris, E
dc.coverage.spatialUnited States
dc.date.accessioned2023-09-26T08:38:23Z
dc.date.available2023-09-26T08:38:23Z
dc.date.issued2023-07-01
dc.identifier.citationIEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2023, 70 (7), pp. 681 - 692en_US
dc.identifier.issn0885-3010
dc.identifier.urihttps://repository.icr.ac.uk/handle/internal/5984
dc.identifier.eissn1525-8955
dc.identifier.eissn1525-8955
dc.identifier.doi10.1109/TUFFC.2023.3268009
dc.description.abstractDynamic contrast-enhanced ultrasound imaging (DCE-US) may be used to characterize tumor vascular perfusion using metrics derived from time-amplitude curves (TACs). The 3-D DCE-US enables generation of 3-D parametric maps of TAC metrics that may inform on how perfusion varies across the entire tumor. The aim of this work was to understand the effect of low temporal sampling (i.e., < 1 Hz) typical of 3-D imaging using a swept 1-D array transducer on the evaluation of TAC metrics and the effect of transducer motion in combination with flow on 3-D parametric maps generated using both plane wave imaging (PWI) (seven angles) and focused imaging (FI). Correlation maps were introduced to evaluate the spatial blurring of TAC metrics. A research ultrasound scanner and a pulse-inversion algorithm were used to obtain DCE-US. The 2-D (frame rate 10 Hz) and 3-D (volume rate 0.4 Hz) images were acquired of a simple wall-less vessel phantom (flow phantom) and a cartridge phantom. Volumetric imaging provided similar TACs to that of the higher 2-D sampling rate. Varying sweep speed and acceleration/deceleration had little influence on the 3-D TAC compared to 2-D for both FI and PWI. Sweeping motion and limited temporal sampling (0.4 Hz) did not change the spatial correlation of TAC metrics measured using FI, whereas a small increase in correlation across the cartridge phantom was observed for PWI. This was attributed to grating lobe artifacts, broad beam spatial blurring, and incoherent compounding caused by motion. Increased correlation will reduce the spatial resolution with which inhomogeneity of vascular perfusion can be mapped supporting the choice of FI for DCE-US.
dc.formatPrint-Electronic
dc.format.extent681 - 692
dc.languageeng
dc.language.isoengen_US
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INCen_US
dc.relation.ispartofIEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en_US
dc.subjectUltrasonography
dc.subjectPhantoms, Imaging
dc.subjectMotion
dc.subjectContrast Media
dc.subjectAlgorithms
dc.subjectImaging, Three-Dimensional
dc.titleEvaluation of Performance Tradeoffs When Using Mechanically Swept 1-D Linear Arrays for 3-D DCE-US.en_US
dc.typeJournal Article
dcterms.dateAccepted2023-07-01
dc.date.updated2023-09-26T08:36:52Z
rioxxterms.versionVoRen_US
rioxxterms.versionofrecord10.1109/TUFFC.2023.3268009en_US
rioxxterms.licenseref.startdate2023-07-01
rioxxterms.typeJournal Article/Reviewen_US
pubs.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/37067961
pubs.issue7
pubs.organisational-groupICR
pubs.organisational-groupICR/Primary Group
pubs.organisational-groupICR/Primary Group/ICR Divisions
pubs.organisational-groupICR/Primary Group/ICR Divisions/Radiotherapy and Imaging
pubs.organisational-groupICR/Primary Group/ICR Divisions/Radiotherapy and Imaging/Imaging for Radiotherapy Adaptation
pubs.organisational-groupICR/Primary Group/ICR Divisions/Radiotherapy and Imaging/Ultrasound & Optical Imaging
pubs.publication-statusPublished
pubs.publisher-urlhttp://dx.doi.org/10.1109/tuffc.2023.3268009
pubs.volume70
icr.researchteamImaging Radiother Adapten_US
icr.researchteamUltrasound & Optic Imagen_US
dc.contributor.icrauthorMoghimirad, Elahe
dc.contributor.icrauthorBamber, Jeffrey
icr.provenanceDeposited by Mr Arek Surman on 2023-09-26. Deposit type is initial. No. of files: 1. Files: Evaluation_of_Performance_Tradeoffs_When_Using_Mechanically_Swept_1-D_Linear_Arrays_for_3-D_DCE-US.pdf


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record

http://creativecommons.org/licenses/by/4.0/
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/