dc.description.abstractUsing digitalized whole slide images (WSI) in routine histopathology practice is a revolutionary technology. This study aims to assess the clinical impacts of WSI quality and representation of the corresponding glass slides. 40,160 breast WSIs were examined and compared with their corresponding glass slides. The presence, frequency, location, tissue type, and the clinical impacts of missing tissue were assessed. Scanning time, type of the specimens, time to WSIs implementation, and quality control (QC) measures were also considered. The frequency of missing tissue ranged from 2% to 19%. The area size of the missed tissue ranged from 1-70%. In most cases (>75%), the missing tissue area size was <10% and peripherally located. In all cases the missed tissue was fat with or without small entrapped normal breast parenchyma. No missing tissue was identified in WSIs of the core biopsy specimens. QC measures improved images quality and reduced WSI failure rates by seven-fold. A negative linear correlation between the frequency of missing tissue and both the scanning time and the image file size was observed (p < 0.05). None of the WSI with missing tissues resulted in a change in the final diagnosis. Missing tissue on breast WSI is observed but with variable frequency and little diagnostic consequence. Balancing between WSI quality and scanning time/image file size should be considered and pathology laboratories should undertake their own assessments of risk and provide the relevant mitigations with the appropriate level of caution.
dc.formatPrint-Electronic
dc.format.extent903 - 910
dc.languageeng
dc.language.isoeng
dc.publisherELSEVIER SCIENCE INC
dc.relation.ispartofModern Pathology
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectBreast
dc.subjectHumans
dc.titlePotential quality pitfalls of digitalized whole slide image of breast pathology in routine practice.
dc.typeJournal Article
dcterms.dateAccepted2021-12-12
dc.date.updated2024-01-12T12:50:09Z
rioxxterms.versionVoR
rioxxterms.versionofrecord10.1038/s41379-021-01000-8
rioxxterms.licenseref.startdate2022-07-01
rioxxterms.typeJournal Article/Review
pubs.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/34961765
pubs.issue7
pubs.organisational-groupICR
pubs.organisational-groupICR/Primary Group
pubs.organisational-groupICR/Primary Group/ICR Divisions
pubs.organisational-groupICR/Primary Group/ICR Divisions/Molecular Pathology
pubs.organisational-groupICR/Primary Group/ICR Divisions/Molecular Pathology/Integrated Pathology
pubs.organisational-groupICR/ImmNet
pubs.publication-statusPublished
pubs.publisher-urlhttp://dx.doi.org/10.1038/s41379-021-01000-8
pubs.volume35
icr.researchteamIntegrated Pathology
dc.contributor.icrauthorSalto-Tellez, Manuel
icr.provenanceDeposited by Mr Arek Surman (impersonating Prof Manuel Salto-Tellez) on 2024-01-12. Deposit type is initial. No. of files: 1. Files: Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice.pdf


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record

http://creativecommons.org/licenses/by/4.0/
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/