Now showing items 1-10 of 13
A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking.
(ELSEVIER IRELAND LTD, 2016-04-01)
PURPOSE: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive ...
Review of ultrasound image guidance in external beam radiotherapy part II: intra-fraction motion management and novel applications.
(IOP PUBLISHING LTD, 2016-04-21)
Imaging has become an essential tool in modern radiotherapy (RT), being used to plan dose delivery prior to treatment and verify target position before and during treatment. Ultrasound (US) imaging is cost-effective in ...
The impact of 2D cine MR imaging parameters on automated tumor and organ localization for MR-guided real-time adaptive radiotherapy.
(IOP PUBLISHING LTD, 2018-11-22)
2D cine MR imaging may be utilized to monitor rapidly moving tumors and organs-at-risk for real-time adaptive radiotherapy. This study systematically investigates the impact of geometric imaging parameters on the ability ...
Principal component analysis fosr fast and model-free denoising of multi b-value diffusion-weighted MR images.
(IOP PUBLISHING LTD, 2019-04-09)
Despite the utility of tumour characterisation using quantitative parameter maps from multi-b-value diffusion-weighted MRI (DWI), clinicians often prefer the use of the image with highest diffusion-weighting (b-value), for ...
Synthetic 4D-CT of the thorax for treatment plan adaptation on MR-guided radiotherapy systems.
(IOP PUBLISHING LTD, 2019-05-23)
MR-guided radiotherapy treatment planning utilises the high soft-tissue contrast of MRI to reduce uncertainty in delineation of the target and organs at risk. Replacing 4D-CT with MRI-derived synthetic 4D-CT would support ...
Realizing the potential of magnetic resonance image guided radiotherapy in gynaecological and rectal cancer.
(BRITISH INST RADIOLOGY, 2019-05-14)
CT-based radiotherapy workflow is limited by poor soft tissue definition in the pelvis and reliance on rigid registration methods. Current image-guided radiotherapy and adaptive radiotherapy models therefore have limited ...
Treatment planning optimization with beam motion modeling for dynamic arc delivery of SBRT using Cyberknife with multileaf collimation.
(WILEY, 2019-12-01)
PURPOSE: The use of dynamic arcs for delivery of stereotactic body radiation therapy (SBRT) on Cyberknife is investigated, with a view to improving treatment times. This study investigates the required modeling of robot ...
Lung volume reproducibility under ABC control and self-sustained breath-holding.
(WILEY, 2017-03-01)
An Active Breathing Coordinator (ABC) can be employed to induce breath-holds during CT imaging and radiotherapy of lung, breast and liver cancer, and recently during lung cancer MRI. The apparatus measures and controls ...
Real-time 4D dose reconstruction for tracked dynamic MLC deliveries for lung SBRT.
(WILEY, 2016-11-01)
PURPOSE: This study provides a proof of concept for real-time 4D dose reconstruction for lung stereotactic body radiation therapy (SBRT) with multileaf collimator (MLC) tracking and assesses the impact of tumor tracking ...
A generalized framework unifying image registration and respiratory motion models and incorporating image reconstruction, for partial image data or full images.
(IOP PUBLISHING LTD, 2017-06-07)
Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image ...