Search
Now showing items 1-10 of 11
A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking.
(ELSEVIER IRELAND LTD, 2016-04-01)
PURPOSE: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive ...
Lung stereotactic body radiotherapy with an MR-linac - Quantifying the impact of the magnetic field and real-time tumor tracking.
(ELSEVIER IRELAND LTD, 2016-06-01)
BACKGROUND AND PURPOSE: There are concerns that radiotherapy doses delivered in a magnetic field might be distorted due to the Lorentz force deflecting secondary electrons. This study investigates this effect on lung ...
Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy.
(WILEY, 2015-12-01)
PURPOSE: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can ...
Evaluation of three presets for four-dimensional cone beam CT in lung radiotherapy verification by visual grading analysis.
(BRITISH INST RADIOLOGY, 2016-07-01)
OBJECTIVE: To evaluate three image acquisition presets for four-dimensional cone beam CT (CBCT) to identify an optimal preset for lung tumour image quality while minimizing dose and acquisition time. METHODS: Nine patients ...
The impact of 2D cine MR imaging parameters on automated tumor and organ localization for MR-guided real-time adaptive radiotherapy.
(IOP PUBLISHING LTD, 2018-11-22)
2D cine MR imaging may be utilized to monitor rapidly moving tumors and organs-at-risk for real-time adaptive radiotherapy. This study systematically investigates the impact of geometric imaging parameters on the ability ...
Synthetic 4D-CT of the thorax for treatment plan adaptation on MR-guided radiotherapy systems.
(IOP PUBLISHING LTD, 2019-05-23)
MR-guided radiotherapy treatment planning utilises the high soft-tissue contrast of MRI to reduce uncertainty in delineation of the target and organs at risk. Replacing 4D-CT with MRI-derived synthetic 4D-CT would support ...
Treating locally advanced lung cancer with a 1.5T MR-Linac - Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy.
(ELSEVIER IRELAND LTD, 2017-11-01)
PURPOSE: This study investigates the feasibility and potential benefits of radiotherapy with a 1.5T MR-Linac for locally advanced non-small cell lung cancer (LA NSCLC) patients. MATERIAL AND METHODS: Ten patients with LA ...
Edge effects in 3D dosimetry: characterisation and correction of the non-uniform dose response of PRESAGE®.
(IOP PUBLISHING LTD, 2020-05-04)
Previous work has shown that PRESAGE® can be used successfully to perform 3D dosimetric measurements of complex radiotherapy treatments. However, measurements near the sample edges are known to be difficult to achieve. ...
T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.
(LIPPINCOTT WILLIAMS & WILKINS, 2017-10-01)
OBJECTIVES: The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D ...
Real-time 4D dose reconstruction for tracked dynamic MLC deliveries for lung SBRT.
(WILEY, 2016-11-01)
PURPOSE: This study provides a proof of concept for real-time 4D dose reconstruction for lung stereotactic body radiation therapy (SBRT) with multileaf collimator (MLC) tracking and assesses the impact of tumor tracking ...