Search
Now showing items 1-10 of 43
Dose verification of dynamic MLC-tracked radiotherapy using small PRESAGE (R) 3D dosimeters and a motion phantom
(IOP PUBLISHING LTD, 2019-01-01)
Characterization of small PRESAGE (R) samples for measurements near the dosimeter edges
(IOP PUBLISHING LTD, 2019-01-01)
A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking.
(ELSEVIER IRELAND LTD, 2016-04-01)
PURPOSE: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive ...
Lung stereotactic body radiotherapy with an MR-linac - Quantifying the impact of the magnetic field and real-time tumor tracking.
(ELSEVIER IRELAND LTD, 2016-06-01)
BACKGROUND AND PURPOSE: There are concerns that radiotherapy doses delivered in a magnetic field might be distorted due to the Lorentz force deflecting secondary electrons. This study investigates this effect on lung ...
Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy.
(WILEY, 2015-12-01)
PURPOSE: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can ...
Evaluation of three presets for four-dimensional cone beam CT in lung radiotherapy verification by visual grading analysis.
(BRITISH INST RADIOLOGY, 2016-07-01)
OBJECTIVE: To evaluate three image acquisition presets for four-dimensional cone beam CT (CBCT) to identify an optimal preset for lung tumour image quality while minimizing dose and acquisition time. METHODS: Nine patients ...
Evaluation of radiotherapy techniques for radical treatment of lateralised oropharyngeal cancers : Dosimetry and NTCP.
(URBAN & VOGEL, 2016-08-01)
AIM: The aim of this study was to investigate potential advantages and disadvantages of three-dimensional conformal radiotherapy (3DCRT), multiple fixed-field intensity-modulated radiotherapy (IMRT) and volumetric-modulated ...
The impact of 2D cine MR imaging parameters on automated tumor and organ localization for MR-guided real-time adaptive radiotherapy.
(IOP PUBLISHING LTD, 2018-11-22)
2D cine MR imaging may be utilized to monitor rapidly moving tumors and organs-at-risk for real-time adaptive radiotherapy. This study systematically investigates the impact of geometric imaging parameters on the ability ...
Novel adaptive beam-dependent margins for additional OAR sparing.
(IOP PUBLISHING LTD, 2018-10-29)
Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability ...