Search
Now showing items 1-1 of 1
Dose prescription with spatial uncertainty for peripheral lung SBRT.
(2019-01)
Current clinical practice is to prescribe to 95% of the planning target volume (PTV) in 4D stereotactic body radiotherapy (SBRT) for lung. Frequently the PTV margin has a very low physical density so that the internal ...