Search
Now showing items 1-7 of 7
Evaluation of radiotherapy techniques for radical treatment of lateralised oropharyngeal cancers : Dosimetry and NTCP.
(URBAN & VOGEL, 2016-08-01)
AIM: The aim of this study was to investigate potential advantages and disadvantages of three-dimensional conformal radiotherapy (3DCRT), multiple fixed-field intensity-modulated radiotherapy (IMRT) and volumetric-modulated ...
Novel adaptive beam-dependent margins for additional OAR sparing.
(IOP PUBLISHING LTD, 2018-10-29)
Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability ...
Edge effects in 3D dosimetry: characterisation and correction of the non-uniform dose response of PRESAGE®.
(IOP PUBLISHING LTD, 2020-05-04)
Previous work has shown that PRESAGE® can be used successfully to perform 3D dosimetric measurements of complex radiotherapy treatments. However, measurements near the sample edges are known to be difficult to achieve. ...
Geometric and dosimetric evaluations of atlas-based segmentation methods of MR images in the head and neck region.
(IOP Publishing, 2018-07-11)
Owing to its excellent soft-tissue contrast, magnetic resonance (MR) imaging has found an increased application in radiation therapy (RT). By harnessing these properties for treatment planning, automated segmentation methods ...
Online dose reconstruction for tracked volumetric arc therapy: Real-time implementation and offline quality assurance for prostate SBRT.
(WILEY, 2017-08-20)
PURPOSE: Firstly, this study provides a real-time implementation of online dose reconstruction for tracked volumetric arc therapy (VMAT). Secondly, this study describes a novel offline quality assurance tool, based on ...
Iterative framework for the joint segmentation and CT synthesis of MR images: application to MRI-only radiotherapy treatment planning.
(IOP PUBLISHING LTD, 2017-06-07)
To tackle the problem of magnetic resonance imaging (MRI)-only radiotherapy treatment planning (RTP), we propose a multi-atlas information propagation scheme that jointly segments organs and generates pseudo x-ray computed ...
First evaluation of the feasibility of MLC tracking using ultrasound motion estimation.
(WILEY, 2016-08-01)
PURPOSE: To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. METHODS: The Clarity calibration and quality ...