Synthetic 4D-CT of the thorax for treatment plan adaptation on MR-guided radiotherapy systems.
(IOP PUBLISHING LTD, 2019-05-23)
MR-guided radiotherapy treatment planning utilises the high soft-tissue contrast of MRI to reduce uncertainty in delineation of the target and organs at risk. Replacing 4D-CT with MRI-derived synthetic 4D-CT would support ...
Treating locally advanced lung cancer with a 1.5T MR-Linac - Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy.
(ELSEVIER IRELAND LTD, 2017-11-01)