Slice Encoding for Metal Artefact Correction in magnetic resonance imaging examinations for radiotherapy planning.
(ELSEVIER IRELAND LTD, 2016-08-01)
BACKGROUND AND PURPOSE: Magnetic resonance (MR) and computed tomography (CT) images are degraded in the presence of metallic implants. We investigate whether SEMAC (Slice Encoding for Metal Artifact Correction) MR is ...
Oxygen-Enhanced MRI Accurately Identifies, Quantifies, and Maps Tumor Hypoxia in Preclinical Cancer Models.
(AMER ASSOC CANCER RESEARCH, 2015-11-19)
There is a clinical need for noninvasive biomarkers of tumor hypoxia for prognostic and predictive studies, radiotherapy planning, and therapy monitoring. Oxygen-enhanced MRI (OE-MRI) is an emerging imaging technique for ...
Standard and Hypofractionated Dose Escalation to Intraprostatic Tumor Nodules in Localized Prostate Cancer: Efficacy and Toxicity in the DELINEATE Trial.
(ELSEVIER SCIENCE INC, 2020-03-15)
PURPOSE: To report a planned analysis of the efficacy and toxicity of dose escalation to the intraprostatic dominant nodule identified on multiparametric magnetic resonance imaging using standard and hypofractionated ...
Metal-based imaging agents: progress towards interrogating neurodegenerative disease.
(ROYAL SOC CHEMISTRY, 2020-05-21)
Central nervous system (CNS) neurodegeneration is defined by a complex series of pathological processes that ultimately lead to death. The precise etiology of these disorders remains unknown. Recent efforts show that a ...
Volumetry of the dominant intraprostatic tumour lesion: intersequence and interobserver differences on multiparametric MRI.
(BRITISH INST RADIOLOGY, 2017-03-01)
OBJECTIVE: To establish the interobserver reproducibility of tumour volumetry on individual multiparametric (mp) prostate MRI sequences, validate measurements with histology and determine whether functional to morphological ...
Iterative framework for the joint segmentation and CT synthesis of MR images: application to MRI-only radiotherapy treatment planning.
(IOP PUBLISHING LTD, 2017-06-07)
To tackle the problem of magnetic resonance imaging (MRI)-only radiotherapy treatment planning (RTP), we propose a multi-atlas information propagation scheme that jointly segments organs and generates pseudo x-ray computed ...
Evaluation of a multi-atlas CT synthesis approach for MRI-only radiotherapy treatment planning.
(ELSEVIER SCI LTD, 2017-03-01)