A method to verify sections of arc during intrafraction portal dosimetry for prostate VMAT.
(2019-10-16)
This study investigates the use of a running sum of images during segment-resolved intrafraction portal dosimetry for volumetric modulated arc therapy (VMAT), so as to alert the operator to an error before it becomes ...
A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking.
(ELSEVIER IRELAND LTD, 2016-04-01)
PURPOSE: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive ...
Lung stereotactic body radiotherapy with an MR-linac - Quantifying the impact of the magnetic field and real-time tumor tracking.
(ELSEVIER IRELAND LTD, 2016-06-01)
BACKGROUND AND PURPOSE: There are concerns that radiotherapy doses delivered in a magnetic field might be distorted due to the Lorentz force deflecting secondary electrons. This study investigates this effect on lung ...
Evaluation of radiotherapy techniques for radical treatment of lateralised oropharyngeal cancers : Dosimetry and NTCP.
(URBAN & VOGEL, 2016-08-01)
AIM: The aim of this study was to investigate potential advantages and disadvantages of three-dimensional conformal radiotherapy (3DCRT), multiple fixed-field intensity-modulated radiotherapy (IMRT) and volumetric-modulated ...
Novel adaptive beam-dependent margins for additional OAR sparing.
(IOP PUBLISHING LTD, 2018-10-29)
Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability ...
Improving fiducial and prostate capsule visualization for radiotherapy planning using MRI.
(WILEY, 2019-03-01)
BACKGROUND AND PURPOSE: Intraprostatic fiducial markers (FM) improve the accuracy of radiotherapy (RT) delivery. Here we assess geometric integrity and contouring consistency using a T2*-weighted (T2*W) sequence alone, ...
Magnetic Resonance Imaging-Guided Adaptive Radiation Therapy: A "Game Changer" for Prostate Treatment?
(ELSEVIER SCIENCE INC, 2018-02-01)
Radiation therapy to the prostate involves increasingly sophisticated delivery techniques and changing fractionation schedules. With a low estimated α/β ratio, a larger dose per fraction would be beneficial, with moderate ...
Spect perfusion imaging versus CT for predicting radiation injury to normal lung in lung cancer patients.
(BRITISH INST RADIOLOGY, 2019-09-01)
OBJECTIVES: In non-small cell lung cancer (NSCLC) patients, to establish whether the fractional volumes of irradiated anatomic or perfused lung differed between those with and without deteriorating lung function or radiation ...
A novel amplitude binning strategy to handle irregular breathing during 4DMRI acquisition: improved imaging for radiotherapy purposes.
(BMC, 2019-05-14)
BACKGROUND: For radiotherapy of abdominal cancer, four-dimensional magnetic resonance imaging (4DMRI) is desirable for tumor definition and the assessment of tumor and organ motion. However, irregular breathing gives rise ...
Towards real-time photon Monte Carlo dose calculation in the cloud.
(IOP Publishing Ltd, 2017-06-07)
Near real-time application of Monte Carlo (MC) dose calculation in clinic and research is hindered by the long computational runtimes of established software. Currently, fast MC software solutions are available utilising ...