Realizing the potential of magnetic resonance image guided radiotherapy in gynaecological and rectal cancer.
(BRITISH INST RADIOLOGY, 2019-05-14)
CT-based radiotherapy workflow is limited by poor soft tissue definition in the pelvis and reliance on rigid registration methods. Current image-guided radiotherapy and adaptive radiotherapy models therefore have limited ...
Beam selection for stereotactic ablative radiotherapy using Cyberknife with multileaf collimation.
(ELSEVIER SCI LTD, 2018-12-20)
The Cyberknife system (Accuray Inc., Sunnyvale, CA) enables radiotherapy using stereotactic ablative body radiotherapy (SABR) with a large number of non-coplanar beam orientations. Recently, a multileaf collimator has also ...
Automatic reconstruction of the delivered dose of the day using MR-linac treatment log files and online MR imaging.
(ELSEVIER IRELAND LTD, 2020-01-10)
BACKGROUND AND PURPOSE: Anatomical changes during external beam radiotherapy prevent the accurate delivery of the intended dose distribution. Resolving the delivered dose, which is currently unknown, is crucial to link ...
Dosimetric accuracy of delivering SBRT using dynamic arcs on Cyberknife.
(WILEY, 2020-04-01)
PURPOSE: Several studies have demonstrated potential improvements in treatment time through the use of dynamic arcs for delivery of stereotactic body radiation therapy (SBRT) on Cyberknife. However, the delivery system has ...
Combining radiation with hyperthermia: a multiscale model informed by in vitro experiments.
(ROYAL SOC, 2018-01-01)
Combined radiotherapy and hyperthermia offer great potential for the successful treatment of radio-resistant tumours through thermo-radiosensitization. Tumour response heterogeneity, due to intrinsic, or micro-environmentally ...
Treating locally advanced lung cancer with a 1.5T MR-Linac - Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy.
(ELSEVIER IRELAND LTD, 2017-11-01)
PURPOSE: This study investigates the feasibility and potential benefits of radiotherapy with a 1.5T MR-Linac for locally advanced non-small cell lung cancer (LA NSCLC) patients. MATERIAL AND METHODS: Ten patients with LA ...
Magnetic Resonance Imaging-Guided Adaptive Radiation Therapy: A "Game Changer" for Prostate Treatment?
(ELSEVIER SCIENCE INC, 2018-02-01)
Radiation therapy to the prostate involves increasingly sophisticated delivery techniques and changing fractionation schedules. With a low estimated α/β ratio, a larger dose per fraction would be beneficial, with moderate ...
Investigating the effect of a magnetic field on dose distributions at phantom-air interfaces using PRESAGE® 3D dosimeter and Monte Carlo simulations.
(IOP PUBLISHING LTD, 2018-02-26)
Dosimetric quality assurance (QA) of the new Elekta Unity (MR-linac) will differ from the QA performed of a conventional linac due to the constant magnetic field, which creates an electron return effect (ERE). In this work ...
Feasibility of MR-guided ultrahypofractionated radiotherapy in 5, 2 or 1 fractions for prostate cancer.
(ELSEVIER IRELAND LTD, 2021-01-01)
The drive towards hypofractionated prostate radiotherapy is motivated by a low alpha/beta ratio for prostate cancer (1 to 3 Gy) compared to surrounding organs at risk, implying an improved therapeutic ratio with increasing ...
Feasibility of magnetic resonance guided radiotherapy for the treatment of bladder cancer.
(ELSEVIER IRELAND LTD, 2020-11-01)
Whole bladder magnetic resonance image-guided radiotherapy using the 1.5 Telsa MR-linac is feasible. Full online adaptive planning workflow based on the anatomy seen at each fraction was performed. This was delivered within ...