Show simple item record

dc.contributor.authorBussmann, S
dc.contributor.authorLuechinger, R
dc.contributor.authorFroehlich, JM
dc.contributor.authorvon Weymarn, C
dc.contributor.authorReischauer, C
dc.contributor.authorKoh, DM
dc.contributor.authorGutzeit, A
dc.date.accessioned2019-02-20T07:49:07Z
dc.date.issued2018-01
dc.identifier.citationPloS one, 2018, 13 (10), pp. e0204220 - ?
dc.identifier.issn1932-6203
dc.identifier.urihttps://repository.icr.ac.uk/handle/internal/3063
dc.identifier.eissn1932-6203
dc.identifier.doi10.1371/journal.pone.0204220
dc.description.abstractObjectives The paucity of safety information on intrauterine devices (IUD) for magnetic resonance imaging (MRI) examinations is clinically relevant. The aim of this study is to evaluate the MRI safety of clinically used IUDs composed of copper/gold and stainless steel at 1.5T and 3.0T.Materials and methods We assessed and compared the displacement force, torque effects, presence of imaging artifacts and heating of IUDs composed of copper/gold (western IUDs) and stainless steel (China) on 1.5 and 3.0T MRI systems.Results Gold/Copper IUDs can show small deflection angles of 7° ± 7° in the worst-case field gradient of 40T/m (equivalent to magnetic force of 0.5 mN), while the stainless steel IUD experienced significant magnetic force and deflection (Force > 7.5 N; deflection angle 90° ± 1°). Manual rotation and suspension method show no torque effects on gold/copper IUDs but high torque effects were observed by manual rotation on the stainless steel IUD. Heating measurements showed a temperature increase (rescaled to a wbSAR of 4 W/kg) of 1.4°C at 1.5T / 3.4°C at 3.0 T (stainless steel IUD), 3.2°C at 1.5 T / 3.8°C at 3 T (copper/gold IUD), 3.3°C at 1.5 T / 4.8°C at 3 T (copper 1), 3.8°C at 1.5 T / 4.8°C at 3 T (copper 2). The visible imaging artifacts of the copper and gold IUDs at 3 T MRI reach a diameter of 4 mm ± 1 mm, while the stainless steel IUD resulted in artifacts measuring 200mm ± 10 mm when using gradient echo pulse sequences.Conclusions Standard IUDs (copper/gold) can be considered as conditional for MR safety at 1.5 T and 3.0 T, demonstrating at wbSAR up to 4W/kg and a magnetic field gradient of up to 40T/m with minimal imaging artifacts. The stainless steel IUD, however, induces unacceptable artifacts and is potentially harmful to patients during MRI due to high magnetic dislocation forces and torque (MR unsafe).
dc.formatElectronic-eCollection
dc.format.extente0204220 - ?
dc.languageeng
dc.language.isoeng
dc.rights.urihttps://creativecommons.org/licenses/by/4.0
dc.subjectHumans
dc.subjectGold
dc.subjectStainless Steel
dc.subjectMagnetic Resonance Imaging
dc.subjectArtifacts
dc.subjectIntrauterine Devices
dc.subjectIntrauterine Devices, Copper
dc.subjectTorque
dc.subjectFemale
dc.titleSafety of intrauterine devices in MRI.
dc.typeJournal Article
dcterms.dateAccepted2018-09-05
rioxxterms.versionofrecord10.1371/journal.pone.0204220
rioxxterms.licenseref.urihttps://creativecommons.org/licenses/by/4.0
rioxxterms.licenseref.startdate2018-01
rioxxterms.typeJournal Article/Review
dc.relation.isPartOfPloS one
pubs.issue10
pubs.notesNot known
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/Royal Marsden Clinical Units
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/Royal Marsden Clinical Units
pubs.publication-statusPublished
pubs.volume13
pubs.embargo.termsNot known
dc.contributor.icrauthorKoh, Dow-Mu


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record

https://creativecommons.org/licenses/by/4.0
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by/4.0