Show simple item record

dc.contributor.authorBussmann, Sen_US
dc.contributor.authorLuechinger, Ren_US
dc.contributor.authorFroehlich, JMen_US
dc.contributor.authorvon Weymarn, Cen_US
dc.contributor.authorReischauer, Cen_US
dc.contributor.authorKoh, DMen_US
dc.contributor.authorGutzeit, Aen_US
dc.coverage.spatialUnited Statesen_US
dc.date.accessioned2019-02-20T07:49:07Z
dc.date.issued2018en_US
dc.identifierhttps://www.ncbi.nlm.nih.gov/pubmed/30300364en_US
dc.identifierPONE-D-17-34046en_US
dc.identifier.citationPLoS One, 2018, 13 (10), pp. e0204220 - ?en_US
dc.identifier.urihttps://repository.icr.ac.uk/handle/internal/3063
dc.identifier.eissn1932-6203en_US
dc.identifier.doi10.1371/journal.pone.0204220en_US
dc.description.abstractOBJECTIVES: The paucity of safety information on intrauterine devices (IUD) for magnetic resonance imaging (MRI) examinations is clinically relevant. The aim of this study is to evaluate the MRI safety of clinically used IUDs composed of copper/gold and stainless steel at 1.5T and 3.0T. MATERIALS AND METHODS: We assessed and compared the displacement force, torque effects, presence of imaging artifacts and heating of IUDs composed of copper/gold (western IUDs) and stainless steel (China) on 1.5 and 3.0T MRI systems. RESULTS: Gold/Copper IUDs can show small deflection angles of 7° ± 7° in the worst-case field gradient of 40T/m (equivalent to magnetic force of 0.5 mN), while the stainless steel IUD experienced significant magnetic force and deflection (Force > 7.5 N; deflection angle 90° ± 1°). Manual rotation and suspension method show no torque effects on gold/copper IUDs but high torque effects were observed by manual rotation on the stainless steel IUD. Heating measurements showed a temperature increase (rescaled to a wbSAR of 4 W/kg) of 1.4°C at 1.5T / 3.4°C at 3.0 T (stainless steel IUD), 3.2°C at 1.5 T / 3.8°C at 3 T (copper/gold IUD), 3.3°C at 1.5 T / 4.8°C at 3 T (copper 1), 3.8°C at 1.5 T / 4.8°C at 3 T (copper 2). The visible imaging artifacts of the copper and gold IUDs at 3 T MRI reach a diameter of 4 mm ± 1 mm, while the stainless steel IUD resulted in artifacts measuring 200mm ± 10 mm when using gradient echo pulse sequences. CONCLUSIONS: Standard IUDs (copper/gold) can be considered as conditional for MR safety at 1.5 T and 3.0 T, demonstrating at wbSAR up to 4W/kg and a magnetic field gradient of up to 40T/m with minimal imaging artifacts. The stainless steel IUD, however, induces unacceptable artifacts and is potentially harmful to patients during MRI due to high magnetic dislocation forces and torque (MR unsafe).en_US
dc.format.extente0204220 - ?en_US
dc.languageengen_US
dc.language.isoengen_US
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en_US
dc.subjectArtifactsen_US
dc.subjectFemaleen_US
dc.subjectGolden_US
dc.subjectHumansen_US
dc.subjectIntrauterine Devicesen_US
dc.subjectIntrauterine Devices, Copperen_US
dc.subjectMagnetic Resonance Imagingen_US
dc.subjectStainless Steelen_US
dc.subjectTorqueen_US
dc.titleSafety of intrauterine devices in MRI.en_US
dc.typeJournal Article
dcterms.dateAccepted2018-09-05en_US
rioxxterms.versionofrecord10.1371/journal.pone.0204220en_US
rioxxterms.licenseref.startdate2018en_US
rioxxterms.typeJournal Article/Reviewen_US
dc.relation.isPartOfPLoS Oneen_US
pubs.issue10en_US
pubs.notesNot knownen_US
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/Royal Marsden Clinical Units
pubs.publication-statusPublished onlineen_US
pubs.volume13en_US
pubs.embargo.termsNot knownen_US
dc.contributor.icrauthorKoh, Dow-Muen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

http://creativecommons.org/licenses/by/4.0/
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/