Show simple item record

dc.contributor.authorBedford, JL
dc.coverage.spatialEngland
dc.date.accessioned2023-09-05T09:33:35Z
dc.date.available2023-09-05T09:33:35Z
dc.date.issued2023-08-29
dc.identifier.citationPhysics in Medicine and Biology, 2023,en_US
dc.identifier.issn0031-9155
dc.identifier.urihttps://repository.icr.ac.uk/handle/internal/5951
dc.identifier.eissn1361-6560
dc.identifier.eissn1361-6560
dc.identifier.doi10.1088/1361-6560/acf4de
dc.description.abstractThe aim of this work is to develop a discrete ordinates Boltzmann solver that can be used for calculation of absorbed dose from both photons and protons within an inverse planning optimizer, so as to perform accurate dose calculation throughout the whole of the inverse planning process. With photons, five transport sweeps were performed to obtain scattered photon fluence, and unscattered electron fluence was then obtained and used as a fixed source for solution of the electron transport equations. With protons, continuous slowing down was treated as a fixed source, and five transport sweeps were used to calculate scattered fluence. The total electron or proton fluence was multiplied by the stopping power ratio for the transport medium to obtain absorbed dose. The method was evaluated in homogeneous media and in a lung case where the planning target volume was surrounded by low-density lung material. Photon arc, proton passive scattering and proton arc treatments were considered. The results were compared to a clinically validated convolution dose calculation for photons, and with an analytical method for protons. In water-equivalent media, the discrete ordinates method agrees with the alternative algorithms to within 2%. Convergence is found to be sufficiently complete for water-, lung- and bone-equivalent materials after five iterations. The dose calculated by the relatively simple angular quadrature is seen to be very close to that calculated by a more comprehensive quadrature. For inhomogeneous lung plans, the method shows more heterogeneity of dose to the planning target volume than the comparative methods. The discrete ordinates Boltzmann solver provides a general framework for dose calculation with both photons and protons. The method is suitable for incorporation into an inverse planning optimizer, so that accurate dose calculation in a heterogeneous medium can be obtained throughout inverse planning, with the result that the final dose distribution is as predicted by the optimiser.
dc.formatPrint-Electronic
dc.languageeng
dc.language.isoengen_US
dc.publisherIOP Publishingen_US
dc.relation.ispartofPhysics in Medicine and Biology
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en_US
dc.subjectInverse planning
dc.subjectLinear Boltzmann transport equations
dc.subjectVMAT
dc.subjectdiscrete ordinates
dc.subjectproton therapy
dc.titleA discrete ordinates Boltzmann solver for application to inverse planning of photons and protons.en_US
dc.typeJournal Article
dcterms.dateAccepted2023-08-29
dc.date.updated2023-09-04T07:16:32Z
rioxxterms.versionAMen_US
rioxxterms.versionofrecord10.1088/1361-6560/acf4deen_US
rioxxterms.licenseref.startdate2023-08-29
rioxxterms.typeJournal Article/Reviewen_US
pubs.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/37643625
pubs.organisational-group/ICR
pubs.organisational-group/ICR/Primary Group
pubs.organisational-group/ICR/Primary Group/Royal Marsden Clinical Units
pubs.publication-statusPublished online
pubs.publisher-urlhttp://dx.doi.org/10.1088/1361-6560/acf4de
dc.contributor.icrauthorBedford, James L
icr.provenanceDeposited by James L Bedford on 2023-09-04. Deposit type is initial. No. of files: 1. Files: BoltzmannInversePlanningClean.pdf


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record

http://creativecommons.org/licenses/by/4.0/
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/