Show simple item record

dc.contributor.authorBedford, JL
dc.date.accessioned2024-01-12T15:53:19Z
dc.date.available2024-01-12T15:53:19Z
dc.date.issued2024-02-02
dc.identifier.citationPhysics in Medicine and Biology, 2024,
dc.identifier.issn0031-9155
dc.identifier.urihttps://repository.icr.ac.uk/handle/internal/6104
dc.identifier.eissn1361-6560
dc.identifier.eissn1361-6560
dc.identifier.doi10.1088/1361-6560/ad1cf7
dc.identifier.doi10.1088/1361-6560/ad1cf7
dc.description.abstractObjective. A discrete ordinates Boltzmann solver has recently been developed for use as a fast and accurate dose engine for calculation of photon and proton beams. The purpose of this study is to apply the algorithm to the inverse planning process for photons and protons and to evaluate the impact that this has on the quality of the final solution.Approach.The method was implemented into an iterative least-squares inverse planning optimiser, with the Boltzmann solver used every 20 iterations over the total of 100 iterations. Elemental dose distributions for the intensity modulation and the dose changes at the intermediate iterations were calculated by a convolution algorithm for photons and a simple analytical model for protons. The method was evaluated for 12 patients in the heterogeneous tissue environment encountered in radiotherapy of lung tumours. Photon arc and proton arc treatments were considered in this study. The results were compared with those for use of the Boltzmann solver solely at the end of inverse planning or not at all.Main results.Application of the Boltzmann solver at the end of inverse planning shows the dose heterogeneity in the planning target volume to be greater than calculated by convolution and empirical methods, with the median root-mean-square dose deviation increasing from 3.7 to 5.3 for photons and from 1.9 to 3.4 for proton arcs. Use of discrete ordinates throughout inverse planning enables homogeneity of target coverage to be maintained throughout, the median root-mean-square dose deviation being 3.6 for photons and 2.3 for protons. Dose to critical structures is similar with discrete ordinates and conventional methods. Time for inverse planning with discrete ordinates takes around 1-2 h using a contemporary computing environment.Significance.By incorporating the Boltzmann solver into an iterative least squares inverse planning optimiser, accurate dose calculation in a heterogeneous medium is obtained throughout inverse planning, with the result that the final dose distribution is of the highest quality.
dc.language.isoeng
dc.publisherIOP Publishing Ltd
dc.relation.ispartofPhysics in Medicine and Biology
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleInverse planning of lung radiotherapy with photon and proton beams using a discrete ordinates Boltzmann solver.
dc.typeJournal Article
dcterms.dateAccepted2024-01-10
dc.date.updated2024-01-11T12:14:07Z
rioxxterms.versionAM
rioxxterms.versionofrecord10.1088/1361-6560/ad1cf7
rioxxterms.licenseref.startdate2024-01-10
rioxxterms.typeJournal Article/Review
pubs.organisational-groupICR
pubs.organisational-groupICR/Primary Group
pubs.organisational-groupICR/Primary Group/Royal Marsden Clinical Units
pubs.publication-statusPublished online
pubs.publisher-urlhttp://dx.doi.org/10.1088/1361-6560/ad1cf7
dc.contributor.icrauthorBedford, James L
icr.provenanceDeposited by James L Bedford on 2024-01-11. Deposit type is initial. No. of files: 1. Files: InversePlanningWithBoltzmannClean.pdf


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record

https://creativecommons.org/licenses/by-nc-nd/4.0/
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by-nc-nd/4.0/