Dose prescription with spatial uncertainty for peripheral lung SBRT.
(2019-01)
Current clinical practice is to prescribe to 95% of the planning target volume (PTV) in 4D stereotactic body radiotherapy (SBRT) for lung. Frequently the PTV margin has a very low physical density so that the internal ...
A method to verify sections of arc during intrafraction portal dosimetry for prostate VMAT.
(2019-10-16)
This study investigates the use of a running sum of images during segment-resolved intrafraction portal dosimetry for volumetric modulated arc therapy (VMAT), so as to alert the operator to an error before it becomes ...
Worst case optimization for interfractional motion mitigation in carbon ion therapy of pancreatic cancer.
(2016-10-07)
Introduction The efficacy of radiation therapy treatments for pancreatic cancer is compromised by abdominal motion which limits the spatial accuracy for dose delivery - especially for particles. In this work we investigate ...
Mean heart dose variation over a course of breath-holding breast cancer radiotherapy.
(2016-11)
Objective The purpose of the work was to estimate the dose received by the heart throughout a course of breath-holding breast radiotherapy.Methods 113 cone-beam CT (CBCT) scans were acquired for 20 patients treated within ...
Calculation of absorbed dose in radiotherapy by solution of the linear Boltzmann transport equations.
(2019-01-10)
Over the last decade, dose calculations which solve the linear Boltzmann transport equations have been introduced into clinical practice and are now in widespread use. However, knowledge in the radiotherapy community ...
International Guideline on Dose Prioritization and Acceptance Criteria in Radiation Therapy Planning for Nasopharyngeal Carcinoma.
Purpose The treatment of nasopharyngeal carcinoma requires high radiation doses. The balance of the risks of local recurrence owing to inadequate tumor coverage versus the potential damage to the adjacent organs at risk ...
A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking.
(ELSEVIER IRELAND LTD, 2016-04-01)
PURPOSE: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive ...
Lung stereotactic body radiotherapy with an MR-linac - Quantifying the impact of the magnetic field and real-time tumor tracking.
(ELSEVIER IRELAND LTD, 2016-06-01)
BACKGROUND AND PURPOSE: There are concerns that radiotherapy doses delivered in a magnetic field might be distorted due to the Lorentz force deflecting secondary electrons. This study investigates this effect on lung ...
Prospective Study Delivering Simultaneous Integrated High-dose Tumor Boost (≤70 Gy) With Image Guided Adaptive Radiation Therapy for Radical Treatment of Localized Muscle-Invasive Bladder Cancer.
(ELSEVIER SCIENCE INC, 2016-04-01)
PURPOSE: Image guided adaptive radiation therapy offers individualized solutions to improve target coverage and reduce normal tissue irradiation, allowing the opportunity to increase the radiation tumor dose and spare ...
Does breast composition influence late adverse effects in breast radiotherapy?
(CHURCHILL LIVINGSTONE, 2016-04-01)
BACKGROUND: Large breast size is associated with increased risk of late adverse effects after surgery and radiotherapy for early breast cancer. It is hypothesised that effects of radiotherapy on adipose tissue are responsible ...